Submersible pump cable: flat, round, two and three wire

This is the cable that hangs in a well for twenty years. It is bought in short lengths, installed once, and rarely seen again until the pump fails.

CountySandusky
RegionNorthwest Ohio
Typical lot12/2 and 10/3, 100-500 ft
FormFlat or round, twisted

Request a quote

Tell the desk what you have in Submersible pump cable

Send the basics and a buyer reviews the lot, usually the same working day.

  • Reviewed by a buyer, not a scale
  • Reels, pallets, partials or a full truckload
  • Anywhere in Ohio, one desk
  1. 01Send the wire type, quantity and pickup city.
  2. 02A buyer reviews the lot and replies with a basis.
  3. 03Freight and release are agreed, then the load is booked.
614-715-3047

Lot details

Everything helps, but the wire type, the quantity and the pickup city are enough to start.

No account, no upload. Photos can follow by text to 614-715-3047.

A long aisle of large wooden cable reels under a high warehouse roof.

Flat against round, and why both exist

Submersible pump cable is a 600-volt assembly of two or three insulated conductors with a ground, made specifically to hang in a well alongside a drop pipe. The flat form is moulded into a ribbon so it can be taped to the pipe without building a lump that catches on the casing. The round form is twisted and jacketed, used where the run is in open water or where the well is large enough that a ribbon is awkward.

Both are built with a tough outer jacket, usually PVC or a nylon-reinforced PVC, because the cable is dragged over a casing lip and then sits in water for decades. The conductors are stranded, not solid, so the cable can flex as the water level and the pump move.

Two-wire and three-wire are not the same job

A two-wire pump has the starting components built into the motor, so the cable carries two conductors plus ground and lands directly on the motor leads. A three-wire pump needs a control box at the surface with the start capacitor and relay, so the cable carries three conductors plus ground and one of them is the start winding.

That is why 12/2 and 10/3 are the two sizes most often in stock, and why a roll of 10/3 cannot substitute for 12/2 on a two-wire pump. When a lot is described, the conductor count matters more than the gauge. A seller who says only ten-gauge has described half of what a buyer needs.

Depth, gauge and the splice that decides the life

Well depth sets the gauge. A shallow jet conversion in a forty-foot well may take 12/2; a three-hundred-foot submersible needs heavier conductors to keep voltage drop within reason, and the run from the wellhead to the pressure tank is part of the calculation. A pump that fails early is often a voltage-drop failure rather than a motor failure.

The other weak point is the splice. Cable is joined to the motor leads with a sealed splice kit, and that splice sits in water. A replaced pump leaves the old cable in the well or hauls it out in one piece, and a cable that comes out with a swollen, hardened splice at the bottom is a cable that has been wet on the inside.

Farm and rural water work

Sandusky County and the flat, drain-tiled ground around Fremont run on wells: farmsteads, grain operations, rural residences and small water systems. Every pump replacement strands a length of drop cable, and much of it is pulled, coiled and stored in a barn against the day it is needed again.

That stored cable is usually a single length cut at the pitless adapter, which makes it measurable. What it is not is tagged, and a coil of flat cable in a barn has no print left on the outside face because the print was on the side that faced the pipe.

  • Conductor count and gauge, for example 12/2 or 10/3
  • Flat or round, and whether the jacket is intact end to end
  • Length as cut, and whether the splice end is included
  • Condition of the bottom end: swollen, hardened or clean
  • Whether the cable was pulled from a working well or a failed one

Related pages

Adjacent cities, wire families and regional briefs.

Questions sellers ask

Can well cable be reused after a pump replacement?

Often yes. If the jacket is intact and the length reaches from the pitless adapter to the control box with a few feet to spare, it can go back into service. Cable that has been cut short at both ends, or that has a hardened factory splice on it, is usually cut back or replaced.

Is submersible pump cable the same as ordinary buried cable?

No. It is a specific assembly rated for continuous immersion, with a jacket built to survive in water and a flat or twisted form made to hang with a drop pipe. USE-2 and URD are buried service conductors, and neither is intended to hang in a well.

What lengths are worth listing?

Anything long enough to reach a control box from a wellhead is worth listing, which in practice means fifty feet and up. Shorter pieces are handled as assorted footage. Measure along the cable rather than reading a coil diameter, since flat cable coils unevenly.

Request a quote

Tell the desk what you have in Submersible pump cable

Send the basics and a buyer reviews the lot, usually the same working day.

  • Reviewed by a buyer, not a scale
  • Reels, pallets, partials or a full truckload
  • Anywhere in Ohio, one desk
  1. 01Send the wire type, quantity and pickup city.
  2. 02A buyer reviews the lot and replies with a basis.
  3. 03Freight and release are agreed, then the load is booked.
614-715-3047

Second look at the lot

Everything helps, but the wire type, the quantity and the pickup city are enough to start.

No account, no upload. Photos can follow by text to 614-715-3047.

Call 614-715-3047 Request a quote