Green means one thing only
An insulated equipment grounding conductor is green, or green with a yellow stripe, and it may not be used for anything else. That single rule is why grounding wire is so often left over: a crew buys a coil for the ground path, uses part of it, and the remainder cannot be burned up on a phase conductor later.
The conductor itself is ordinary copper, usually stranded above 10 AWG, with the same thermoplastic insulation as building wire. Some of it is dual marked and can be used in wet locations; some is not. The print on the green jacket tells you which, in the same repeating string as any other building wire.
Sizing does not follow the phase conductor
A common mistake at the desk is to assume the ground is the same size as the hots. It is not, above a certain point. The equipment grounding conductor is sized from the overcurrent device protecting the circuit, not from the current-carrying conductors, which is why a 4/0 feeder often carries a 2 AWG ground.
That has a practical consequence for surplus. Big feeder jobs produce small grounding conductors in quantity and large ones rarely. A pallet of green 6 and 4 AWG out of a distribution upgrade is normal and useful; a coil of green 4/0 is unusual and usually came from a service or a grounding electrode run.
Bare grounding inside cable and tray
Not all equipment grounding conductor is green. Cable assemblies carry a bare ground, and tray and pull boxes often use bare conductor for bonding. Bare grounding conductor is pulled from the same reels as any building wire and is identifiable only by size, which makes it the part of a mixed lot that gets mis-sorted. A bare grounding conductor pulled alongside phase conductors also carries their jacket marks, and often a film of pulling lubricant that has to be wiped off before the copper can be judged.
There is also the bonding jumper: short lengths, often with a lug already crimped on one end, made up on site for a door, a disconnect or a section of tray. Those are more assembly than wire, and they should be listed as such rather than tossed into a coil pile where the lugs will punch through the insulation of everything around them.
Sorting a mixed grounding lot
Grounding lots are almost always mixed, and they are mixed in a specific way: many small coils, several gauges, green and bare together, and a handful of jumpers with lugs. The sort is quick if the sizes are stated and slow if they are not.
- Gauge and whether the conductor is stranded or solid
- Green insulated or bare, counted separately
- Length of each coil, with short pieces grouped by gauge
- Print on the green jacket, including any wet rating
- Jumpers and lugged assemblies kept out of the coil pile
Related pages
Adjacent cities, wire families and regional briefs.
More in conductor metal and grounding
All wire typesQuestions sellers ask
Can green wire be used for anything but grounding?
No, and that is why it accumulates. The colour identifies the conductor permanently, so a partial coil cannot be reassigned to a phase or a switch leg. Its only uses are equipment grounding, bonding and grounding electrode conductors, which is a smaller market than building wire but a steady one.
Why is the ground smaller than the feeder?
Because it is sized from the overcurrent protective device rather than from the phase conductors. A large feeder on a modest breaker takes a comparatively small equipment grounding conductor. That is why big jobs leave behind small green coils and almost no large ones.
Do you buy grounding wire mixed with other colours?
It can be reviewed, but it is sorted first, and the green is separated out because it moves on its own. A mixed pallet where the green has already been pulled and counted will be handled faster than one where the colours are still interleaved.
Request a quote
Tell the desk what you have in Grounding conductor
Send the basics and a buyer reviews the lot, usually the same working day.
- Reviewed by a buyer, not a scale
- Reels, pallets, partials or a full truckload
- Anywhere in Ohio, one desk
- 01Send the wire type, quantity and pickup city.
- 02A buyer reviews the lot and replies with a basis.
- 03Freight and release are agreed, then the load is booked.
Second look at the lot
Everything helps, but the wire type, the quantity and the pickup city are enough to start.