Wire brief · Building and service wire
NM-B cable: 14/2 through 6/3, coils and cut lengths
NM-B is the cable behind most Ohio houses. It is also the cable most likely to be sitting half-used on a shelf, because residential work never consumes a coil neatly.
Request a quote
Tell the desk what you have in NM-B and Romex cable
Send the basics and a buyer reviews the lot, usually the same working day.
- Reviewed by a buyer, not a scale
- Reels, pallets, partials or a full truckload
- Anywhere in Ohio, one desk
- 01Send the wire type, quantity and pickup city.
- 02A buyer reviews the lot and replies with a basis.
- 03Freight and release are agreed, then the load is booked.
Lot details
Everything helps, but the wire type, the quantity and the pickup city are enough to start.

Two or three conductors under a PVC jacket
NM-B is a factory assembly of two, three or four insulated conductors plus a bare equipment ground, all wrapped in a flame-retardant PVC jacket and filled to a round or flat profile. It is a 600-volt cable for dry locations, run through stud bays, joist spaces and attic floors, secured with staples and protected by nail plates where it passes close to a framing face.
The conductors are rated 90°C, but the cable is applied at the 60°C ampacity column, which is why a 12 AWG NM-B circuit is a 20-amp circuit and not more. That limitation is printed nowhere the seller will see, and it is the reason an inspector asks for the jacket print rather than accepting a size from memory.
Reading the size: 14/2 through 6/3
The first number is the conductor gauge and the second is the count of insulated conductors, ground excluded. So 14/2 is two 14 AWG conductors plus a bare ground, and 12/3 is three 12 AWG conductors plus ground. The common residential set runs 14/2 for lighting, 12/2 for receptacles and kitchen circuits, 10/2 and 10/3 for dryers and air handlers, and 6/3 for ranges and service feeds to outbuildings.
The larger sizes are where the money and the weight sit, and where partial coils are most common. A 6/3 range run takes thirty-five feet out of a fifty-foot coil, leaving fifteen. A 10/3 dryer run leaves more. Those remainders are numerous and individually small, and they are the reason a residential contractor's shelf looks the way it does.
Why partial NM-B coils accumulate
Retail packaging drives it. Big-box coils come in 25, 50, 125 and 250 feet, and a job that needs eighty feet buys a hundred and keeps twenty. Over a season a three-man crew builds a shelf of these, each coil banded with its own tag, none long enough for the next job and none short enough to throw away.
Then there is the removed cable. A kitchen remodel pulls old NM-B out of the walls, and it comes out in short kinked runs with staples still in it. That material is a different thing from a coil: the jacket is deformed, the conductors are work-hardened, and the length is whatever the wall allowed.
How a partial coil is judged
Two things separate a resaleable coil from scrap: the print and the condition. The jacket print gives the size, the type and the listing, and it survives most handling. Sun is the enemy, since NM-B is not sunlight rated and a coil left on a truck bed through a summer goes brittle and fades. Staples and pulled bends are the second enemy.
- Size and conductor count from the jacket print
- Remaining length measured, or the original coil length stated
- Whether the coil is still in its retail band and tag
- Jacket condition: brittle, faded, stapled or kinked
- Removed cable kept apart from unused coil stock
Related pages
Adjacent cities, wire families and regional briefs.
More in building and service wire
All wire typesQuestions sellers ask
Do you take part coils from a retail store tag?
Yes. The band and tag are useful because they state the original length and the size, which saves measuring. Note how much has been used, even approximately, and photograph the tag alongside the coil so the two can be tied together.
Is NM-B that was pulled out of a wall reusable?
Rarely as cable. It comes out kinked and stapled, the jacket is deformed at every staple, and the lengths are short. It is handled as copper recovery. An untouched coil on a shelf is a different category and should never be mixed into the same pile.
Does NM-B have a sunlight rating?
No. It is a dry-location cable and it is not listed for sunlight exposure. A coil that sat outdoors will have a chalked, brittle jacket on the exposed side even if the inner wraps look sound, so storage history is worth stating when the coil has been outside.
Request a quote
Tell the desk what you have in NM-B and Romex cable
Send the basics and a buyer reviews the lot, usually the same working day.
- Reviewed by a buyer, not a scale
- Reels, pallets, partials or a full truckload
- Anywhere in Ohio, one desk
- 01Send the wire type, quantity and pickup city.
- 02A buyer reviews the lot and replies with a basis.
- 03Freight and release are agreed, then the load is booked.
Second look at the lot
Everything helps, but the wire type, the quantity and the pickup city are enough to start.