Wire brief · Building and service wire

USE-2 cable: buried service laterals and remote runs

One conductor, buried, then rising into a meter base where the sun hits it for twenty years. USE-2 is rated for both halves of that life, and the print has to prove it.

CountyHancock
RegionNorthwest Ohio
Typical lot2 AWG to 350 kcmil
Rating90°C wet, sunlight resistant

Request a quote

Tell the desk what you have in USE-2 cable

Send the basics and a buyer reviews the lot, usually the same working day.

  • Reviewed by a buyer, not a scale
  • Reels, pallets, partials or a full truckload
  • Anywhere in Ohio, one desk
  1. 01Send the wire type, quantity and pickup city.
  2. 02A buyer reviews the lot and replies with a basis.
  3. 03Freight and release are agreed, then the load is booked.
614-715-3047

Lot details

Everything helps, but the wire type, the quantity and the pickup city are enough to start.

No account, no upload. Photos can follow by text to 614-715-3047.

Large wooden reels and coils of cable in a yard with plant buildings behind.

A single conductor doing two jobs

USE-2 is an underground service entrance cable: a single insulated conductor, copper or aluminium, rated 90°C in wet locations, marked for direct burial and sunlight resistance. It is not a cable assembly, so a service made from it is two or three separate conductors laid in the same trench, spaced apart, and brought up into a meter base or a disconnect.

The rating that surprises people is sunlight. A buried conductor spends most of its life in the dark, but the last six feet climb a pole or a wall into the meter, and that section is exposed. USE-2 is printed sunlight resistant for exactly that reason. Reels that carry the marking but sat uncovered in a yard for three years are a different question from reels that carry it and were stored under cover.

Moisture is the working condition, not the accident

Wet location is normal for this cable, so the insulation is built for it. The vulnerability is at the ends. A cut USE-2 conductor left open takes water between the strands, and on aluminium that water travels under the insulation by capillary action and starts oxide at the point where the conductor leaves the jacket.

Anyone storing this cable for resale seals the ends, and anyone reviewing a lot checks whether that was done. A reel with taped or heat-shrink-capped ends reads as cared for. A reel with open, whitened ends reads as a length that may have to be cut back a few feet before it is usable, which on a short piece can be most of it.

Tank farms, wellheads and the Findlay pattern

Refining and pipeline operations around Findlay run a lot of small buried services to places that are not buildings: valve sites, sumps, remote lighting, monitoring points at the edge of a tank farm. Those runs are short, they are made up on site from a reel on the truck, and the reel goes back to the shop with a remainder on it.

The same pattern holds on farms and at water and wastewater sites across the northwest counties, where a service is extended to a new pump house or a second meter. It is the reason USE-2 turns up in twos and threes rather than by the pallet, and why so much of it is short lengths that need to be measured rather than read off a tag.

What a USE-2 lot needs to say

Because the cable is single conductor, a lot of it is unidentifiable from shape alone. Size, metal and the print do all the work, and a photograph of the conductor end next to a tape measure is worth taking every time.

  • Size and metal, with a scale in the photograph of the end
  • Type print, including USE-2, RHW-2 or both
  • Length of each piece and how it is coiled
  • Whether the ends are sealed, taped or open
  • Storage: under cover, outdoors, or in a wet floor location

Questions sellers ask

Can USE-2 be run in conduit?

It can, and many installations sleeve the riser in conduit for physical protection. Where the print also carries RHW-2, the conductor is recognised for raceway use as well as direct burial. Where it carries USE-2 only, the run is treated as a buried service conductor.

Why do the cut ends matter so much on this cable?

Water enters stranded conductor at an open end and works its way under the insulation, and aluminium oxides in the presence of that moisture. Sealed ends mean the length is intact. Open, chalky ends mean the first few feet may have to come off, which changes the usable footage.

Do you buy odd short lengths of USE-2?

Yes, measured and listed individually. Short single conductors are useful to contractors doing service extensions, but each one has to be long enough to be worth handling. Photograph them laid out against a tape rather than coiled, so the length reads at a glance.

Request a quote

Tell the desk what you have in USE-2 cable

Send the basics and a buyer reviews the lot, usually the same working day.

  • Reviewed by a buyer, not a scale
  • Reels, pallets, partials or a full truckload
  • Anywhere in Ohio, one desk
  1. 01Send the wire type, quantity and pickup city.
  2. 02A buyer reviews the lot and replies with a basis.
  3. 03Freight and release are agreed, then the load is booked.
614-715-3047

Second look at the lot

Everything helps, but the wire type, the quantity and the pickup city are enough to start.

No account, no upload. Photos can follow by text to 614-715-3047.

Call 614-715-3047 Request a quote