Tray cable: TC and TC-ER in plant tray systems

Tray cable is the wiring method of the plant floor, and the letters after TC decide how far it may leave the tray. That is the first thing to establish about a reel.

CountyLucas
RegionNorthwest Ohio
Typical lot14 AWG to 500 kcmil
Voltage600 V and 2 kV classes

Request a quote

Tell the desk what you have in Tray cable

Send the basics and a buyer reviews the lot, usually the same working day.

  • Reviewed by a buyer, not a scale
  • Reels, pallets, partials or a full truckload
  • Anywhere in Ohio, one desk
  1. 01Send the wire type, quantity and pickup city.
  2. 02A buyer reviews the lot and replies with a basis.
  3. 03Freight and release are agreed, then the load is booked.
614-715-3047

Lot details

Everything helps, but the wire type, the quantity and the pickup city are enough to start.

No account, no upload. Photos can follow by text to 614-715-3047.

Large wooden reels and coils of cable in a yard with plant buildings behind.

TC, TC-ER and the exposed-run allowance

Tray cable is a factory assembly of insulated conductors, with or without a ground, under an overall jacket, listed for use in cable tray. The standard product is a 600-volt cable, and a 2 kV version exists for small motors and feeder branches. Conductors inside are usually THHN or XHHW, and the jacket is PVC or a nylon-covered PVC, printed sunlight resistant and often marked for direct burial.

TC-ER adds an exposed run rating. It permits the cable to leave the tray and run unsupported for a limited distance to the equipment it serves, which is what most plants actually need, because tray stops at the edge of the aisle and the motor does not. A reel printed TC without the ER marking will not satisfy that run, and an electrician will notice before the invoice does.

What a tray system does to cable

Cable in tray is supported but not protected. It sits in the open above a process line, so it takes heat radiating from the equipment below, dust, oil mist and washdown spray. The jacket on the top face chalks and the print fades first, which is why the underside of a coil is usually the readable side.

Fill and weight matter as well. A tray loaded to its permitted fill with a heavy multiconductor bundle sags between rungs, and the jacket takes a set at every rung. That set is a series of flat spots. A used coil with pronounced rung marks is still electrically sound, but it will not lay straight in a new tray, and that belongs in the description.

Panel changeouts and the cut lengths they leave

The reliable generator of tray cable surplus is a controls or drive upgrade. A line is retooled, the old MCC is replaced and the tray to it is re-routed, and the cable that fed the previous arrangement is cut loose. Some of it goes back on a reel. Most of it is a pile of twenty- and forty-foot lengths that were cut to reach a specific terminal.

Toledo's glass and automotive supplier plants produce this in cycles, and so does any process plant with a tray system running above the floor. A changeout lot is reviewed on the lengths and the conductor count far more than on total footage, because a hundred feet in three pieces is a different proposition from a hundred feet in one.

Reviewing a tray cable lot

Ask for the print at the jacket, the conductor count and the length. Then ask how it was stored, because tray cable is often the cable that sat on the loading dock.

  • Whether the print reads TC or TC-ER
  • Conductor count, size and whether a ground is included
  • Voltage class, 600 V or 2 kV
  • Length of each cut piece, listed separately
  • Jacket condition: rung marks, chalking, cuts at the ends

Questions sellers ask

What is the difference between TC and TC-ER?

TC is listed for installation in cable tray. TC-ER carries an additional exposed run rating that allows a length to leave the tray and run to the equipment without conduit, within stated limits. The marking is printed on the jacket, and it changes which jobs a reel can be sold into.

Do you take tray cable cut into short lengths?

Yes, listed individually with the length and conductor count for each piece. Short lengths are useful for equipment drops and motor connections. What does not work is a pile described as a total footage, because the pieces have to be matched to a use before any of them can move.

Can tray cable be direct buried?

Some constructions are marked for direct burial and many are not, so the jacket print decides. Where the marking is present, a tray cable with a sunlight-resistant and burial-rated jacket can serve both roles. Where it is absent, the cable stays in tray and in conduit.

Request a quote

Tell the desk what you have in Tray cable

Send the basics and a buyer reviews the lot, usually the same working day.

  • Reviewed by a buyer, not a scale
  • Reels, pallets, partials or a full truckload
  • Anywhere in Ohio, one desk
  1. 01Send the wire type, quantity and pickup city.
  2. 02A buyer reviews the lot and replies with a basis.
  3. 03Freight and release are agreed, then the load is booked.
614-715-3047

Second look at the lot

Everything helps, but the wire type, the quantity and the pickup city are enough to start.

No account, no upload. Photos can follow by text to 614-715-3047.

Call 614-715-3047 Request a quote