Wire brief · Power cable by voltage class
Cable above 35 kV: oil-filled and solid dielectric
Above 35 kV the cable stops being a commodity and becomes an asset with a paper trail. Ownership, not condition, is usually what decides whether a lot can leave the property.
Request a quote
Tell the desk what you have in High voltage cable
Send the basics and a buyer reviews the lot, usually the same working day.
- Reviewed by a buyer, not a scale
- Reels, pallets, partials or a full truckload
- Anywhere in Ohio, one desk
- 01Send the wire type, quantity and pickup city.
- 02A buyer reviews the lot and replies with a basis.
- 03Freight and release are agreed, then the load is booked.
Lot details
Everything helps, but the wire type, the quantity and the pickup city are enough to start.

What changes above 35 kV
Insulation wall thickness climbs steeply, and with it the importance of the two semiconductive screens that sit either side of the insulation. A nick in the outer screen concentrates stress; a void at the inner screen starts a tree. At distribution voltages those defects are survivable for years. Here they are the failure mode.
The cable also gains a metallic sheath, because at these voltages the electric field must be contained and the insulation must be kept dry. A jacket over the sheath protects it from corrosion. Joints and terminations are made by specializt crews with a shelter over the work, and the cable is tested after installation rather than simply energized.
Oil-filled against solid dielectric
Paper-insulated oil-filled cable uses a lead sheath over oil-impregnated paper, with the oil kept under pressure from tanks or a pressure system. The lead is soft, it fatigues at bends, and any section that has been moved needs its sheath inspected. Oil-filled cable in a plant usually dates from an era when the substation was built around it and is decommissioned in place.
Solid dielectric transmission cable is XLPE or EPR with an extruded screen system, a metallic sheath of corrugated aluminum or lead, and an outer jacket. It looks like a larger version of distribution cable and is treated as a much more delicate object. Storage on a reel is acceptable for long periods indoors, but the ends need sealing and the reel needs to stay on its blocking.
Ownership decides the whole question
Almost all cable in this class belongs to a utility or to an industrial plant with a transmission-level substation. It carries an asset number, it appears on a register, and its removal is an event with a record. Surplus conductor at this level is not left by a loading dock for anyone who asks.
That means a review starts with authority rather than with the cable. Who owns it, who can release it, and what document proves the release. A plant engineer can speak for plant-owned cable. Utility-owned cable needs the utility's own disposal authorization, and that may come through a surplus property group rather than through the local operating center.
Why most lots need a utility release
Metals theft has made every utility careful about sheath, conductor and scrap moving off a property without paperwork. Lead sheath and copper conductor are exactly what a release is designed to track. A buyer who cannot show a release is a buyer a utility will not load.
Practical review therefore runs in this order: confirm ownership, obtain the release in writing, establish whether the cable is de-energized and discharged, then look at construction, footage and sheath condition. Cable that has been cut out of a duct bank in short sections is a different proposition from a full reel, and the difference is worth understanding before anyone commits to a removal plan.
- Written release naming the cable and the quantity
- Confirmation the circuit is de-energized and discharged
- Sheath and jacket condition at every exposed end
- Reel or coil dimensions and how it can be lifted
- Any oil containment needed before the cable is moved
Related pages
Adjacent cities, wire families and regional briefs.
More in power cable by voltage class
All wire typesQuestions sellers ask
Can oil-filled cable be moved at all once it is decommissioned?
It can, but it needs planning rather than a forklift. The oil has to be drained or contained, the lead sheath is easily deformed, and any cut end needs sealing before transport. A lot in this condition is normally dealt with as part of a substation retirement project with the utility's own contractor involved.
Does a plant need the utility involved if it owns the substation?
Only if the utility owns the cable. Many large plants own everything past the metering point, including transmission-level cable inside their fence, and then the plant's own authorization is what matters. Where the utility owns the circuit, its release is required no matter who paid for the original installation.
What documentation should accompany a transmission cable lot?
A release letter identifying the cable and its location, a record showing the circuit is out of service, and whatever construction detail exists, usually a spec number or the jacket print. Test records from the original installation help but are rarely still available. Missing records do not stop a review, they just narrow what the cable can be used for.
Request a quote
Tell the desk what you have in High voltage cable
Send the basics and a buyer reviews the lot, usually the same working day.
- Reviewed by a buyer, not a scale
- Reels, pallets, partials or a full truckload
- Anywhere in Ohio, one desk
- 01Send the wire type, quantity and pickup city.
- 02A buyer reviews the lot and replies with a basis.
- 03Freight and release are agreed, then the load is booked.
Second look at the lot
Everything helps, but the wire type, the quantity and the pickup city are enough to start.